Research Products

Precision micro-environmental control systems for live-cell microscopy. Patented FCS chamber technology delivers ±0.2°C first-surface thermal accuracy at the specimen, with laminar flow perfusion and full compatibility with all microscope brands and imaging modes.

Made in the United States.

Trusted by researchers worldwide for 30+ years

FEATURED

Universal Micro-Environmental Controller

Bioptechs Series 6 is a dual‑channel universal temperature controller that provides non‑PID, closed‑loop thermal control for any two Bioptechs systems (including: FCS Chambers, Delta T, and Objective Heaters) from a single touch‑screen interface. It maintains specimen‑plane temperature with high precision (±0.2 °C in the mammalian range, ±0.5 °C up to 99 °C) while protecting both the sample and microscopy equipment.

FCS4 Flow Chamber

The FCS4® is a parallel-plate perfusion chamber engineered for live-cell imaging on inverted microscopes. A patent-pending twist-lock design delivers a leak-free seal in seconds — no tools required. User-selectable gaskets (50 µm–1 mm) define exact flow geometry and shear force. Compatible with confocal, TIRF, STORM, STED, spinning disk, and widefield imaging modalities. Fully autoclavable and retro-compatible with all FCS2® stage adapters.

Panorama Flow Chamber

The Panorama Chamber is an easy to use large format, parallel plate, imaging flow chamber that is compatible with all forms of microscopy. The chamber base is the same size as a standard 96-well plate 128mm x 85mm, therefore no ‘stage adapter’ is needed to interface a microscope. The system utilizes 64mm x 50mm coverslips with a 50mm x 36mm maximum viewing area for panoramic, high‑resolution imaging of cells, tissues, and suspended specimens.

All Products

Universal Micro-Environmental Controller

Bioptechs Series 6 is a dual‑channel universal temperature controller that provides non‑PID, closed‑loop thermal control for any two Bioptechs systems (including: FCS Chambers, Delta T, and Objective Heaters) from a single touch‑screen interface. It maintains specimen‑plane temperature with high precision (±0.2 °C in the mammalian range, ±0.5 °C up to 99 °C) while protecting both the sample and microscopy equipment.

  • Ideal for high resolution long term imaging experiments 
  • Control any two Bioptechs systems simultaneously
  • ±0.2 °C precision (ambient–60 °C) with no overshoot 61°C – 99°C ±0.5°C
  • Full data logging for reproducible, publication‑ready experiments

#LiveCellImaging #Micro-EnvironmentalControl #CellBiology #Microscopy #SampleController

FCS2® Chamber

The gold-standard closed-system live-cell flow chamber for inverted microscopes. Features patented Microaqueduct™ perfusion and ITO-heated optics for uniform temperature control ±0.2°C across the entire specimen plane — no air curtain required. User-definable gaskets set flow geometry, shear force, and optical cavity volume.

  • User-definable flow geometry
  • All microscopy modes compatible
  • ±0.2 °C precision (ambient–60 °C) with no overshoot 61°C – 99°C ±0.5°C
  • Near-laminar perfusion flow

#LiveCellImaging #Microscopy #FluorescenceMicroscopy #CellBiology #PerfusionChamber #TemperatureControl

FCS3® Chamber

The FCS2®-equivalent system purpose-built for upright microscopes. Combines high-volume laminar flow perfusion with Köhler illumination and precise ITO-based temperature control — the only upright-compatible chamber to do all three. User-selectable gaskets define flow profile and optical cavity.

  • Designed for upright microscopes
  • ±0.2 °C precision (ambient–60 °C) with no overshoot 61°C – 99°C ±0.5°C
  • No-tools assembly
  • Customizable gasket geometry

#LiveCellImaging #Micro-EnvironmentalControl #CellBiology #Microscopy #SampleController

FCS4® Flow Chamber (No Heat)

Bioptechs' most advanced parallel-plate flow cell with a patent-pending twist-lock compression dial for leak-free, tool-free assembly every time. User-selectable gaskets (50 µm–1 mm) define exact flow geometry and shear force. Fully autoclavable, 316 SS wetted parts; retro-compatible with all FCS2® stage adapters.

  • Ideal for high resolution long term imaging experiments 
  • Control any two Bioptechs systems simultaneously
  • FCS2 adapter compatible
  • 50 µm–1 mm gasket options

#LiveCellImaging #FlowChamber #Microscopy #CellBiology #PerfusionChamber #TIRFr

FCS3® Non-Heating Chamber Starter Set

Everything needed to run non-heated perfusion experiments on an upright microscope out of the box. Includes the FCS3 chamber, pressure plate, Microaqueduct Slides, and gasket assortment. Ideal for room-temperature flow studies, particle tracking, and buffer exchange assays.

  • Complete starter bundle
  • Upright microscope ready
  • Room-temp perfusion studies
  • Customizable gasket geometry

#LiveCellImaging #UprightMicroscopy #FlowCell #Perfusion #Microscopy #CellBiology

FCS2® Starter Set

Complete FCS2® system bundle including chamber, FCS controller, stage adapter, and Microaqueduct Slides — everything needed for heated live-cell perfusion imaging on an inverted microscope. The fastest path to precise, publication-ready time-lapse data.

  • Complete starter bundle
  • User-definable flow geometry
  • All microscopy modes compatible
  • ±0.2 °C precision (ambient–60 °C) with no overshoot 61°C – 99°C ±0.5°C
  • Near-laminar perfusion flow

#LiveCellImaging #Microscopy #FluorescenceMicroscopy #TimeLapse #TemperatureControl #Perfusion

FCS3® Starter Set

Complete bundle for heated live-cell perfusion imaging on upright microscopes. Includes FCS3 chamber, FCS controller, stage adapter, and Microaqueduct Slides. Eliminates compatibility guesswork and delivers immediate uniform thermal + flow control.

  • Complete starter bundle
  • Upright microscope ready
  • Room-temp perfusion studies
  • Customizable gasket geometry

#LiveCellImaging #UprightMicroscopy #FlowCell #TemperatureControl #Perfusion #CellBiology

No-Heat Flow Cell (FCS2)

A non-heated version of the FCS2® parallel-plate chamber for room-temperature perfusion applications. All the flow-control and optical advantages of the FCS2® platform — near-laminar flow, user-definable gaskets, and Microaqueduct perfusion — without the thermal components.

  • Upright microscope ready
  • Room-temp perfusion studies
  • Fully autoclavable
  • Customizable gasket geometry

#LiveCellImaging #UprightMicroscopy #FlowCell #Perfusion #Microscopy #CellBiology

Cooled FCS2® (CFCS2)

The FCS2® chamber system configured for sub-ambient specimen cooling. Ideal for cold-temperature biology, yeast studies, cryo-stage imaging, and experiments requiring precise temperature control below ambient. Uses the same Microaqueduct platform for uniform thermal distribution.

  • Sub-ambient cooling capability
  • Invert microscope ready
  • Room-temp perfusion studies
  • Customizable gasket geometry

#LiveCellImaging #CryoMicroscopy #TemperatureControl #Microscopy #CellBiology #Biophysics

Bioptechs Panorama Chamber®

Extra-large parallel-plate imaging flow chamber for 64mm × 50mm coverslips with a 50mm × 36mm imaging area. The 96-well plate footprint (128mm × 85mm) fits any microscope stage without a custom adapter. Ideal for tissue sections, vascular networks, and large-field multi-position imaging.

  • Extra large viewing area
  • 64×50mm coverslip format
  • Room-temp perfusion studies
  • Laminar flow perfusion

#LiveCellImaging #TissueImaging #Microscopy #Histology #VascularBiology #Mechanotransduction #Neurobiology

Delta T™ Starter Set

Complete open-dish environmental control system for long-term time-lapse imaging. ITO-coated glass-bottom culture dishes deliver direct, uniform heat to cells without warming the microscope stage — eliminating Z-axis drift. Includes controller, heated lid, coverglass lid, culture cylinders, and 10 dishes.

  • No Z-axis drift
  • Direct ITO heating to cells
  • ±0.2 °C precision (ambient–60 °C) with no overshoot 61°C – 99°C ±0.5°C
  • late & image same dish

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Delta T™ Stage Adapter

The microscope interface component for the Delta T™ system. Precision-machined to position the ITO-heated culture dish at the correct specimen plane for any brand of inverted microscope. Available in configurations to fit most major microscope models.

  • No Z-axis drift
  • Direct ITO heating to cells
  • Brand-specific configurations
  • Precise dish positioning
  • No stage heating

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Delta T™ Heated Lid

Insulated heated lid for Delta T™ culture dishes that prevents evaporation and condensation during long-term imaging. Provides a warm upper boundary to the dish microenvironment, reducing thermal gradients and maintaining media osmolarity during extended time-lapse experiments.

  • Prevents condensation
  • Reduces thermal gradients
  • Preserves media osmolarity
  • Long-term imaging support

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Delta T™ Coverglass Lid

Optical-quality glass lid for the Delta T™ culture dish that enables transmitted light imaging while maintaining dish closure. Provides an optically clear top boundary for DIC, phase contrast, and brightfield imaging without removing the cover between acquisitions.

  • Optically clear glass lid
  • DIC & phase contrast ready
  • Maintains dish closure
  • Prevents evaporation

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Stable Z™ Starter Set

An economical Z-axis stable specimen warmer for standard 35mm plastic dishes and LabTek chamber slides on inverted microscopes. Uniquely engineered nodal-plane design transmits zero thermal expansion to the stage, eliminating focal drift during time-lapse — without the cost of a full Delta T™ system.

  • Zero Z-axis thermal drift
  • Fits any 35mm plastic dishes
  •  Ambient to 50°C range
  • No stage modification
  • Economical entry system

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Stable Z™ Lab-Tek I & II Warming Adapter

A Stable Z™ warming adapter specifically sized for Nunc Lab-Tek I and II chamber slides. Provides Z-axis stable direct heating to Lab-Tek specimens for time-lapse confocal, widefield, and live-cell fluorescence imaging without a custom stage or major investment.

  • Zero Z-axis drift
  • Multi-well slides
  • Confocal & widefield ready
  • No stage modification

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Stable Z™ Labtek II Heated Lid w/ Gas Port

A heated lid with an integrated gas port for Stable Z™ Lab-Tek II setups. Allows CO2 or humidified gas to be delivered directly to the specimen chamber while maintaining thermal control of the lid surface — enabling long-term physiological imaging in CO2-dependent media.

  • Integrated CO2 gas port
  • Multi-well slide compatible 
  •  Long-term CO2 imaging
  • Physiological media support

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Stable Z™ Heated Lid & Controller

Paired heated lid and controller for Stable Z™ setups. The heated lid prevents condensation and temperature drop at the dish surface while the compact controller maintains precise setpoint regulation. Ideal for long-duration time-lapse with standard labware.

  • Prevents lid condensation
  • Precise controller included
  • Standard labware compatible
  • Long-duration time-lapse

#LiveCellImaging #TimeLapse #CellBiology #Microscopy #ZAxisStability #TemperatureControl

Stable Z™ Stage Adapter

The stage interface for the Stable Z™ specimen warming system. Precision-machined to position heated specimens at the correct focal plane on specific microscope models. Available for most major inverted microscope brands.

  • Zero Z-axis drift
  • Correct focal plane fit
  • Works with Stable Z system
  • Minimal footprint

#Microscopy #LiveCellImaging #StageAdapter #TemperatureControl #ZAxisStability #CellBiology

Thermal Slide Starter Set

A simple, elegant ITO-slide warming system for upright microscopes — no stage adapter, no modification required. Disposable or reusable 25mm × 60mm ITO-coated slides slip into a standard specimen retainer. Direct closed-loop heating uses only 2 watts and reaches setpoint without overshoot. Ideal for yeast and mammalian specimens.

  • No stage adapter needed
  • 2-watt direct ITO heating
  • Reusable or disposable slides
  • Upright scope ready

#UprightMicroscopy #LiveCellImaging #TemperatureControl #Yeast #CellBiology #Microscopy

Thermal Slides (5 pk)

Replacement pack of five 25mm × 60mm ITO-coated glass slides for the Bioptechs Thermal Slide system. Reusable with proper care; optionally used as disposables for sterile single-use experiments. Compatible with all modes of transmitted and reflected light microscopy on upright stages.

  • ITO-coated glass slides
  • 25mm × 60mm format
  • Reusable or disposable
  • All transmitted light modes

#UprightMicroscopy #LiveCellImaging #TemperatureControl #Yeast #CellBiology #Microscopy

Thermal Slide Carrier

The precision-machined carrier that holds Bioptechs Thermal Slides in the standard specimen retainer of an upright microscope stage. Provides electrical contact to the ITO-coated slide and connects to the Thermal Slide Controller for closed-loop temperature regulation.

  • ITO-coated glass slides
  • 25mm × 60mm format
  • No scope modification
  • All transmitted light modes

#UprightMicroscopy #LiveCellImaging #TemperatureControl #Yeast #CellBiology #Microscopy

Thermal Slide Controller & Power Supply

Standalone closed-loop controller for the Bioptechs Thermal Slide system. Digital readout with reference probe, multi-voltage power supply, and controller stand included. Regulates ITO slide temperature with fast response and no overshoot from ambient to physiological setpoints.

  • Digital temp readout
  • Fast response, no overshoot
  • Closed-loop regulation
  • Ambient to 37°C+ range

#UprightMicroscopy #LiveCellImaging #TemperatureControl #Yeast #CellBiology #Microscopy

Objective Heater

Patented thin-film heating band that warms immersion objectives to prevent thermal sinking from specimens during live-cell imaging. The only objective heater that incorporates the thermal profile of the objective into its control loop — regulating temperature at the specimen plane, not just the surface. Fits 14–37mm diameter objectives.

  • ±0.2°C precision
  • Options for all objective sizes
  • Does not damage objective
  • Prevents themal gradient
  • Does not alter focus
#LiveCellImaging #ObjectiveHeater #Microscopy #FluorescenceMicroscopy #TemperatureControl #ConfocalMicroscopy #HighNAObjective #imersionlense

Objective Cooling Collar

Precision-machined ring attachment that circulates chilled fluid around an immersion objective to cool it below ambient — enabling cold-temperature live-cell imaging, cryo-stage experiments, and reduction of photothermal artifacts. Custom-sized to specific objectives; requires recirculating chiller source.

  • Fit to objective
  • Circulating fluid cooling
  • Compatible with chiller source

#CryoMicroscopy #LiveCellImaging #ObjectiveCooling #Biophysics #Microscopy #TemperatureControl

Objective Spacers and Isolators

Thermal spacers and isolators that decouple the objective from the microscope nosepiece turret — essential when heating or cooling an objective. Prevents heat sinking from adjacent objectives and the turret, ensuring the Objective Heater or Cooling Collar performs to specification.

  • Thermally isolates objective
  • Prevents nosepiece heat sink
  • Pairs with objective heater

#Microscopy #ObjectiveHeater #TemperatureControl #LiveCellImaging #CellBiology #Biophysics

Objective Wrench & Pliers Set

Specialized tool set for safely removing decorative collars from immersion objectives — a prerequisite for proper Bioptechs Objective Heater contact and thermal transfer. Prevents objective damage during collar removal. Recommended for all first-time Objective Heater installations.

  • Safe collar removal
  • Prevents objective damage

#Microscopy #ObjectiveHeater #LabTools #LiveCellImaging #MicroscopyTools #CellBiology #objectivetools

Objective Cooling Ring

Supplemental cooling ring accessory for objective temperature management. Works in conjunction with the Objective Cooling Collar and recirculating chiller for enhanced thermal management of high-NA immersion lenses in demanding sub-ambient imaging applications.

  • Sub-ambient cooling assist
  • High-NA lens compatible
  • Works with cooling collar
  • Precision-machined ring

#CryoMicroscopy #ObjectiveCooling #LiveCellImaging #Microscopy #Biophysics #TemperatureControl

Oasis Heater & Cooler

Compact refrigerant-free recirculating chiller/heater for laboratory perfusion applications. Thermoelectric technology rated for 200,000+ hour lifetime holds ±0.1°C across 2–45°C. At 7.5×5×7 inches and 8 lbs, it is one-sixth the size of comparable systems and uses under 200W. RS232 interface for PC control.

  • ±0.1°C precision control
  • 2–45°C operating range
  • 200,000+ hr thermoelectric
  • Refrigerant-free design
  • Compact 8 lb unit

#Perfusion #TemperatureControl #LiveCellImaging #Microscopy #Biophysics #CellBiology

Perfusion Pumps

Miniature single or dual-channel peristaltic pumps with DC gear-motor drive (not stepper) for smooth, step-free media delivery at rates from 0.4 µL/min to 18 mL/min. Eliminates pressure pulses that cause coverslip deflection and focus drift. 9V battery backup; universal power supply included.

  • DC motor: no step pulses
  • 0.4 µL–18 mL/min range
  • Dual or single channel
  • 9V battery backup

#UprightMicroscopy #LiveCellImaging #TemperatureControl #Yeast #CellBiology #Microscopy

CO2 Metering Pump

Precision peristaltic pump for volume-based gas delivery — CO2, mixed gas, or air — to live-cell imaging chambers. Four-roller pumping head with ≤3% calibration error; flow rates from 0.004 to 75.19 mL/min. Programmable with Learn & Repeat™ mode, RS-232 PC control, and non-volatile memory for 40 stored programs.

  • Volume-based gas control
  • 0.004–75.19 mL/min range
  • ≤3% calibration error
  • 40 stored programs

#CO2Control #LiveCellImaging #GasControl #Microscopy #CellBiology #Perfusion

Micro Gas Humidifier

Compact heated bubbler that delivers 100% relative humidity to gas flowing into live-cell imaging chambers at flow rates suitable for microscopy. Prevents pH and osmolarity shifts in CO2-dependent media during long-term time-lapse. Luer refill port; 12VDC at under 2.5 watts.

  • 100% RH gas delivery
  • Prevents pH/osmolarity shift
  • Luer syringe refill port
  • Long-term time-lapse ready

#LiveCellImaging #CO2Control #Humidity #TimeLapse #CellBiology #Microscopy

Pump Tubing Sets

Replacement tubing sets for Bioptechs Micro-Perfusion Pumps. Available in silicone and C-Flex in multiple inside diameters (0.015″–0.093″) as single or dual-channel sets. Terminated with standard 1/16″ barb fittings for compatibility with all Bioptechs chambers and adapters.

  •  Silicone & C-Flex options
  •  0.015″–0.093″ ID sizes
  • Single or dual channel
  • 1/16″ barb fittings

#CO2Control #LiveCellImaging #GasControl #Microscopy #CellBiology #Perfusion

Tygon Tubing

Standard Tygon perfusion tubing compatible with all Bioptechs flow chamber systems and perfusion pumps. Flexible, chemically resistant, and suitable for aqueous media, buffer solutions, and standard cell culture reagents. Sold in bulk lengths for custom perfusion setups.

  • Tygon flexible tubing
  •  Chemically resistant
  • Compatible with all chambers
  • 1/16″ ID standard

#CO2Control #LiveCellImaging #GasControl #Microscopy #CellBiology #Perfusion

1/16″ Perfusion Adapter Set

Adapter set for connecting standard 1/16″ perfusion tubing to Bioptechs flow chambers, perfusion pumps, and reservoirs. Provides leak-free fluid connections for single and dual-channel perfusion setups. Essential plumbing accessories for any Bioptechs perfusion configuration.

  • 1/16″ tubing compatible
  •  Leak-free connections
  • Chamber & pump interface
  • Single & dual channel

#CO2Control #LiveCellImaging #GasControl #Microscopy #CellBiology #Perfusion

Hinged Perfusion Adapter Set (2/set)

Hinged perfusion adapters for connecting flexible tubing to Bioptechs chambers at an angle — reducing mechanical stress on tubing connections and improving stability during long-duration perfusion experiments. Sold in pairs for inlet/outlet configurations.

  • Hinged angle connector
  • Reduces tubing stress
  • Standard 1/16″ compatible
  • Audtoclavable
  • Surgical Steel

#CO2Control #LiveCellImaging #GasControl #Microscopy #CellBiology #Perfusion

40mm Coverslips

High-precision #1.5 borosilicate coverslips in 40mm round format — the standard specimen substrate for all Bioptechs FCS2®, FCS3®, and FCS4® flow chambers. Available in standard and polymer-coated variants. German Schott glass for superior flatness, optical clarity, and chemical compatibility.

  • 40mm round #1.5 format
  • FCS2/3/4 compatible
  • Superior optical flatness

#Microscopy #Coverslip #LiveCellImaging #FluorescenceMicroscopy #CellBiology #TIRF #FISH

30mm Coverslips

High-quality #1.5 borosilicate coverslips in 30mm round format for use with Bioptechs Interchangeable Coverglass Dish and compatible open-dish imaging systems. German glass for consistent thickness and optical clarity.

  • 30mm round #1.5 format
  • Open-dish system compatible
  •  Consistent #1.5 thickness
  • Multiple pack sizes

#CO2Control #LiveCellImaging #GasControl #Microscopy #CellBiology #Perfusion

22mm Coverslip #1.5 Thick (100 Count)

Standard 22mm square #1.5 borosilicate coverslips in a 100-count pack. Compatible with standard Lab-Tek and open-dish systems and usable as Stable Z™ and general widefield/confocal imaging substrates.

  • 22mm square format
  • #1.5 standard thickness
  • Confocal & widefield ready

#Microscopy #Coverslip #CellBiology #FluorescenceMicroscopy #LiveCellImaging #LabSupplies

22mm Coverslip Weight

Precision-machined stainless steel weight for holding 22mm coverslips flat on specimen surfaces in open-dish imaging setups. Prevents coverslip float during media changes or perfusion, ensuring a stable imaging plane throughout the experiment.

  • Holds coverslip flat
  • 22mm coverslip specific
  • Prevents coverslip float
  • Surgical stainless steel
  • Audtoclavable

#Microscopy #Coverslip #CellBiology #FluorescenceMicroscopy #LiveCellImaging #LabSupplies#Microscopy #LiveCellImaging #CellBiology #LabTools #OpenDish #CoverslipHolder